For the complete documentation index, see llms.txt. This page is also available as Markdown.

Device Drop Detection

A Support Application 6 feature that detects and reports physical device drops.

Overview

Use Device Drop Detection to monitor the accelerometer for a free-fall signature followed by an impact spike, and report detected drops as a devicedrop event. This gives fleet operators visibility into physical device damage risk and history without relying on self-reporting.

Device Drop Detection is enabled by default. Free-fall is detected when acceleration drops below 2.0 m/s², impact is detected when acceleration spikes above 25.0 m/s², and a 5000 ms cooldown applies between reported drop events.

User Guide

To configure Device Drop Detection, complete the following steps:

  1. Set dropFreeFallThresholdMs2 to the acceleration value below which motion is treated as free-fall.

  2. Set dropImpactThresholdMs2 to the acceleration spike value that, following a qualifying free-fall, is treated as an impact.

  3. Set dropMinFreeFallDurationMs to filter out brief sensor noise by requiring a minimum free-fall duration.

  4. Set dropCooldownMs to the minimum time between two reported drop events.

Configuration

Configuring Free-Fall Sensitivity

Set dropFreeFallThresholdMs2 to the acceleration value below which motion is treated as free-fall. The default is 2.0:

"bfSupportAgent": {
 "dropFreeFallThresholdMs2": 2.0
}

Configuring Impact Sensitivity

Set dropImpactThresholdMs2 to the acceleration spike value that, following a qualifying free-fall, is treated as an impact. The default is 25.0:

Configuring Minimum Free-Fall Duration

Set dropMinFreeFallDurationMs to the minimum free-fall duration, in milliseconds, before an impact counts as a drop. This filters out brief sensor noise. The default is 80:

Configuring Drop Cooldown

Set dropCooldownMs to the minimum time, in milliseconds, between two reported drop events. The default is 5000:

This table provides the settings for the Device Drop Detection feature.

Configuration
Type
Default
Description

dropFreeFallThresholdMs2

Float

2.0

Acceleration below this value is treated as free-fall

dropImpactThresholdMs2

Float

25.0

Acceleration spike above this value, following a qualifying free-fall, is treated as an impact

dropMinFreeFallDurationMs

Integer

80

Minimum free-fall duration before an impact counts as a drop (filters out brief sensor noise)

dropCooldownMs

Integer

5000

Minimum time between two reported drop events

Putting It All Together

For the example described above, the full configuration for the Device Drop Detection feature is as follows:

Last updated